Keep your doors running, your building safe and your fire doors in compliance. National Overhead Door offers monthly, quarterly and annual preventative maintenance programs for every door on your building, including NFPA 80 fire door inspections and drop testing, for businesses across Buffalo and Western New York.

Fix small problems before they shut you down
Fewer breakdowns
Worn springs, cables, rollers and operators are caught and replaced on your schedule, not in the middle of a shift.
Lower operating costs
Planned service costs less than emergency repairs, and well-maintained doors last longer before they need replacing.
Safer, compliant doors
Safety devices, reversing systems and fire doors are tested and documented to help you meet code and insurance requirements.
One program for every door on your building
Overhead & rolling doors
Sectional, rolling steel and high-speed doors and their operators.
- Lubricate springs, rollers, hinges and bearings
- Inspect and adjust springs, cables, drums and tracks
- Test operators, photo eyes and reversing safety devices
- Check weatherseals, bottom seals and panels
Rolling fire door drop testing
Annual NFPA 80 testing of rolling fire doors and counter fire shutters by IDA-certified technicians.
- Drop test to confirm full, automatic closing
- Check closing speed, governors and release devices
- Inspect fusible links, guides and hardware
- Reset the door and document the results
Swinging fire door inspection
Annual NFPA 80 inspection of fire-rated pedestrian doors and frames.
- Verify labels on doors and frames are present and legible
- Check self-closing and positive latching
- Inspect hinges, closers, hardware and clearances
- Note holes, damage or field modifications
Dock equipment & pedestrian doors
Dock equipment and commercial pedestrian doors added to the same plan.
- Inspect and service dock levelers and restraints
- Check dock seals, shelters and bumpers
- Adjust closers, hinges and exit devices
- Test locks and latching on man doors

Fire door compliance, documented
Fire doors only protect your building if they close and latch when they're needed. Our technicians are professionally trained and hold IDA (International Door Association) certifications in fire door drop testing. They inspect and test each fire door assembly to NFPA 80, correct problems on the spot when possible, and give you a written report you can hand to the fire marshal or your insurance carrier.
Choose the schedule that fits your building
For high-traffic doors at warehouses, distribution centers and busy loading docks that can't afford downtime.
For facilities with steady daily use that want problems caught early, season by season.
For lighter-use doors and required yearly NFPA 80 fire door inspections and drop tests.
Built for commercial accounts
- Net 30–45 day terms upon credit approval
- GPS tracking in every service vehicle for precise, accurate labor billing
- Trained & certified technicians: IDA certifications in fire door drop testing, and many hold OSHA 10 and OSHA 30
- Written inspection reports after every visit
- One team for every door: overhead, fire, dock and pedestrian
- A 24/7 Service Line when something breaks between visits
- 70+ years serving Western New York businesses, A+ BBB rating
Getting started is simple
Request a quote
Tell us about your building and the doors you have, or call (716) 667-3500.
Door survey & plan
We inventory your doors, note their condition and recommend a monthly, quarterly or annual schedule with a clear quote.
Scheduled service & reports
Our technicians service your doors on schedule and send a written report after each visit.
Commercial door maintenance across Western New York
From our Orchard Park location, we serve businesses throughout Buffalo, the Southtowns, the Northtowns and the eastern suburbs.
Preventative maintenance & fire door questions
Are your technicians certified to test fire doors?
Yes. Our technicians are professionally trained and hold IDA (International Door Association) certifications in fire door drop testing, and many also hold OSHA 10 and OSHA 30 certifications. That means your fire doors are tested by qualified people, as NFPA 80 requires, and your documentation is ready for the fire marshal and your insurance carrier.
What does NFPA 80 require for fire doors?
NFPA 80 requires fire door assemblies, including swinging fire doors and rolling fire doors and shutters, to be inspected and tested at least once a year by a qualified person, with written records kept for the authority having jurisdiction. Rolling fire doors must be drop tested to confirm they close fully and reset properly.
How often should commercial doors be serviced?
It depends on how hard your doors work. High-traffic doors at warehouses, distribution centers and loading docks often benefit from monthly or quarterly service, while lighter-use doors may only need an annual visit. We'll recommend a schedule based on your doors and how they're used.
What is a fire door drop test?
A drop test confirms that a rolling fire door or fire shutter will close on its own in a fire. We release the door the way a fire would, check that it closes completely and at a safe speed, then reset it and document the results.
What happens if a door fails inspection?
We'll show you what failed, explain what's needed to correct it and give you a quote for the repair. Once the repair is done, we re-test the door and update your documentation.
Do you provide documentation for the fire marshal and insurance?
Yes. After each inspection you receive a written report listing every door inspected, what was found and what was corrected, so you have records ready for the fire marshal, insurance carriers and auditors.
Can one plan cover all of our doors?
Yes. One preventative maintenance plan can cover your overhead doors, rolling steel doors, fire doors, dock equipment and pedestrian doors, so you have one schedule, one vendor and one set of records.
Ready to set up a maintenance plan?
Request a quote or call us to schedule a door survey for your building.